thankyou
thankyou
The included test.nc file was very useful for initial checkout. It did reveal one small issue. The file is written to repeat. The file is 95,100 lines long. The file runs 3 times, then at 30 minutes and 16 seconds of running, the execution slows to about 1/10th speed. I looked into this and found a memory leak due to the display update rate. I experimented with configuration item 2 in Systems Settings Display response during working. I changed the default from 4000 to 1000 and this disrupted smooth operation and steppers lost steps. Tried the other direction and changed it to 5000. This fixed the issue and the test.nc file ran without a hitch for 10 hours. I can see where firmware updates can cause this. I would recommend anyone running firmware version 2019-07-23-112NOR to update that value from 4000, to 5000 to fix the issue. I do like the updated firmware as the DRO boxes show both sets of coordinates. Very nice. Shows DRO and Absolute machine. In regards to the slowdown,